RETROFIT FITTINGS

Retrofit Fitting S Series

The Retrofit S Series is used for internal, one-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in singlewall sumps. Retrofit S fitting kits are universal for round or flat sump walls and the split design doesn’t require excavation or disconnecting pipe. Models available for size-over-size, coaxial FRP, & rigid conduit. Quality FRP construction provides long term compliance solutions.

  • No need to break concrete or disconnect pipe
  • For flat or round walls
  • Accommodates extreme angles
  • 30-year corrosion warranty
  • UL 2447 listed
RF-EPOXY-REQ'D

Retrofit Split FRP Retrofit Entry Fittings for Rigid Pipe,
Round or Flat Singlewall FRP Sumps (RF EPOXY REQ’D)

Pipe TypePart #DescriptionRF EPOXY
REQ'D Qty
Flange
Diameter
1/2" conduit 5"
flange
RF-05-01-U1/2" conduit split, round or flat sump wallEP100RF5"
3/4" conduit 5"
flange
RF-07-01-U 3/4" conduit split, round or flat sump wallEP100RF5"
1" conduit 5"
flange
RF-10-01-U1" conduit split, round or flat sump wallEP100RF5"
1/2" conduit 5"
flange
RF-05-02-U1/2" conduit, round or flat sump wallEP100RF5"
3/4" conduit 7"
flange
RF-07-02-U3/4" conduit 7" flange, split, round or flat sump waEP100RF7"
1" conduit 7"
flange
RF-10-02-U1" conduit 7" flange, split, round or flat sump wallEP100RF7"
2" FRP 7" flangeRF-20-01-U2" FRP 7" flange, split, round or flat sump wallEP100RF (X2)7"
3" FRP 7" flangeRF-30-01-U3" FRP 7" flange, split, round or flat sump wallEP100RF (X2)7"
4" FRP 8" flangeRF-40-01-U4" FRP 8" flange, split, round or flat sump wallEP100RF (X2)8"
6" FRP 11" flangeRF-60-01-U6" FRP 11" flange, split, round or flat sump wallEP100RF (X4)11"
2" FRP 9" flangeRF-20-02-U2" FRP 9" flange, split, round or flat sump wallEP100RF (X2)9"
3" FRP 9" flangeRF-30-02-U3" FRP 9" flange, split, round or flat sump wallEP100RF (X2)9"
2" LCX 7" flangeRF-20L-01-U2" LCX 7" flange, split, round or flat sump wallEP100RF (X2)7"
3" LCX 7" flangeRF-30L-01-U3" LCX 7" flange, split, round or flat sump wallEP100RF (X2)7"
4" LCX 8" flangeRF-40L-01-U4" LCX 8" flange, split, round or flat sump wallEP100RF (X2)8"
2" LCX 9" flangeRF-20L-02-U2" LCX 9" flange, split, round or flat sump wallEP100RF (X2)9'
3" LCX 9" flangeRF-30L-02-U3" LCX 9" flange, split, round or flat sump wallEP100RF (X2)9"

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fitting RLX Series

The RLX Series is used for internal, one-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in singlewall sumps. RLX fitting kits are universal for round or flat sump walls and the split design doesn’t require excavation or disconnecting pipe. Models available for all common flex pipe and semi-rigid piping. Quality FRP construction provides long term compliance solutions.

  • No need to break concrete or disconnect pipe
  • For flat or round walls
  • Accommodates extreme angles
  • 3-year warranty
  • Included FRP sleeve seals to plastic piping, plastic adhesive required
  • UL 2447 listed
RLX-Series

RLX Series Split FRP Retrofit Entry Fittings for Flex Pipe, Round or Flat Singlewall FRP Sump; RF Epoxy, Plastic Adhesives Required; see Flex Pipe ID chart

Pipe TypePart #DescriptionRF EPOXY
REQ'D Qty
PLASTIC
ADHESIVE
REQ'D
A
3/4" coaxial flex
pipe
RLX-1.0-01-U 3/4" coaxial flex pipe, split, round or flat sump wallEP100RF35ml5"
1" coaxial flex
pipe
RLX-1.4-01-U 3/4" coaxial flex pipe, split, round or flat sump wallEP100RF35ml5"
1.5" coaxial flex
pipe
RLX-2.0-01-U 3/4" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)50ml7"
1.75" coaxial
flex pipe
RLX-2.2-01-U1.75" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)50ml7"
2" coaxial
flex pipe
RLX-2.5-01-U2" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)65ml7"
2" coaxial
flex pipe
RLX-2.7-01-U2" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)65ml7"
1.5" coaxial
flex pipe
RLX-2.0-02-U1.5" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)50ml9"
1.75" coaxial
flex pipe
RLX-2.2-02-U1.75" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)50ml9"
2" coaxial
flex pipe
RLX-2.5-02-U2" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)65ml9"
2" coaxial
flex pipe
RLX-2.7-02-U2" coaxial flex pipe, split, round or flat sump wallEP100RF(X2)65ml9"
50mm O.D PE
pipe
RLX-50-01-U50mm O.D pipe, split, round or flat sump wallEP100RF(X2)50ml7"
63mm O.D PE
pipe
RLX-63-01-U63mm O.D pipe, split, round or flat sump wallEP100RF(X2)65ml7"
75mm O.D PE
pipe
RLX-75-01-U70mm O.D pipe, split, round or flat sump wallEP100RF(X2)65ml7"
90mm O.D PE
pipe
RLX-90-01-U90mm O.D pipe, split, round or flat sump wallEP100RF(X2)85ml7"
110mm O.D PE
pipe
RLX-110-01-U110mm O.D pipe, split, round or flat sump wallEP100RF(X2)85ml8"
120mm O.D ductRLX-120-01-U120mm O.D pipe, split, round or flat sump wallEP100RF(X2)85ml8"
125mm O.D PE
pipe
RLX-125-01-U125mm O.D pipe, split, round or flat sump wallEP100RF(X2)100ml8"
60mm O.D PE
pipe
RLX-160-01-U160mm O.D pipe, split, round or flat sump wallEP100RF(X2)100ml12"
50mm O.D PE
pipe
RLX-50-02-U50mm O.D pipe, split, round or flat sump wallEP100RF(X2)50ml9"
63mm O.D PE
pipe
RLX-63-02-U63mm O.D pipe, split, round or flat sump wallEP100RF(X2)65ml9"
75mm O.D PE
pipe
RLX-75-02-U75mm O.D pipe, split, round or flat sump wallEP100RF(X2)65ml9"
90mm O.D PE
pipe
RLX-90-02-U90mm O.D pipe, split, round or flat sump wallEP100RF(X2)85ml9"

Part #Description
EP100RF7 oz. can Bravo retrofit epoxy; use with PVDF pipe
PE-250250ml polyethylene adhesive cartridge; use for poly pipe and poly sump walls; gun required
NY-260260ml nylon adhesive kit; use with nylon pipe; no gun required
WB-0150ml 20 X expanding water-blocking foam, single cartridge; gun required
WB-2050ml 20 X expanding water-blocking foam, case of 20 cartridges; gun required
WB-GWater-blocking foam dispensing gun
T-MG400250ml - 400ml dual cartridge dispensing gun; use with PE-250 cartridge
orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fitting Studded Direct Replacement

Bravo studded direct replacement retrofits are used for internal, one-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in polyethylene or FRP sumps. This series for flat sump walls with existing studded entry boots. The split design doesn’t require excavation or disconnecting pipe. Models available for size over size, coaxial FRP, rigid conduit, & flexible piping. Quality FRP construction provides long term compliance solutions.

  • No need for excavation or cutting pipe
  • Eliminates rubber boots
  • Attaches to existing studs
  • All common coaxial flex pipes
  • Can be used on poly sumps
  • Offset application available
  • 3-year warranty
  • UL 2447 listed
Direct-Replacement

Direct replacement Studded FRP Retrofit Entry Fitting – Polyethylene or FRP Flat-Sided Sumps; Rigid and Flexible Piping Models; RF EPOXY/PLAS ADH REQ’D; See Flex-Pipe ID Chart for selection

Pipe Type Part # DescriptionRF EPOXY
REQ'D Qty
Bolt pattern Pipe
adhesive
Wall adhesive
3/4" conduitRF-07-04BS 3/4" conduit pipe, studded-direct replacement splitEP100RF4 bolt smallNA50ml
3/4" conduitRF-07-04B03/4" conduit pipe, studded-direct replacement split EP100RF4boltNA50ml
3/4" conduitRF-07-04BL 3/4" conduit pipe, studded-direct replacement split EP100RF4 bolt largeNA50ml
1" conduitRF-10-04BS 1" conduit pipe, studded-direct replacement split EP100RF4 bolt smallNA50ml
1" conduitRF-10-04B01" conduit pipe, studded-direct replacement splitEP100RF4boltNA50ml
1" conduitRF-10-04BL 1" conduit pipe, studded-direct replacement splitEP100RF4 bolt largeNA50ml
2" FRPRF-20-08BS2" FRP pipe, studded-direct
replacement split
EP100RF(X2) 8 bolt smallNA65ml
2" FRPRF-20-08B0 2" FRP pipe, studded-direct
replacement split
EP100RF(X2)8 bolt NA65ml
3" FRPRF-30-08BS3" FRP pipe, studded-direct
replacement split
EP100RF(X2)8 bolt smallNA65ml
3" FRPRF-30-08B03" FRP pipe, studded-direct
replacement split
EP100RF(X2)8 bolt NA65ml
3" FRPRF-30-10BS 3" FRP pipe, studded-direct
replacement split
EP100RF(X2)10 bolt smallNA85ml
3" FRPRF-30-10B03" FRP pipe, studded-direct
replacement split
EP100RF(X2)10 bolt NA85ml
4" FRP RF-40-10BS4" FRP pipe, studded-direct
replacement split
EP100RF(X2)10 bolt smallNA85ml
4" FRP RF-40-10B04" FRP pipe, studded-direct
replacement split
EP100RF(X2)10 bolt NA85ml
1.5" coaxial
flex pipe
RLX-2.0-08B0 1.5" coaxial flex pipe, studded-direct replacement split
EP100RF(X2)8 bolt50ml65ml
1.75" coaxial
flex pipe
RLX-2.2-08B0 1.75" coaxial flex pipe, studded-direct replacement split EP100RF(X2)8 bolt50ml65ml
2" coaxial
flex pipe
RLX-2.5-08B02" coaxial flex pipe, studded-direct replacement split
EP100RF(X2)8 bolt65ml65ml

Direct replacement Studded FRP Retrofit Entry Fitting – Polyethylene or FRP Flat-Sided Sumps; Rigid and Flexible Piping Models; RF EPOXY/PLAS ADH REQ’D; See Flex-Pipe ID Chart for selection

Pipe TypePart #DescriptionRF EPOXY
REQ'D Qty
Bolt
pattern
Pipe
adhesive
Wall
adhesive
2" 2.65" O.D
coaxial flex
pipe
RLX-2.7-08B02"/ 2.65" O.D ocoaxial flex pipe,
studded-direct replacement split
EP100RF(X28 bolt65ml65ml
63mm O.D
fusion, 8 bolt
RLX-63-08B063mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X28 bolt65ml65ml
75mm O.D
fusion, 8 bolt
RLX-75-08B075mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X28 bolt65ml65ml
90mm O.D
fusion, 8 bolt
RLX-90-08B090mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X28 bolt85ml65ml
1.5" coaxial
flex pipe
RLX-2.0-10B01.5" coaxial flex pipe, studded-direct
replacement split
EP100RF(X210 bolt50ml85ml
1.75" coaxial
flex pipe
RLX-2.2-10B01.75" coaxial flex pipe, studded-direct
replacement split
EP100RF(X210 bolt50ml85ml
2" 2.5" O.D
coaxial flex
pipe
RLX-2.5-10B02"/ 2.5" O.D coaxial flex pipe, studded-direct replacement split EP100RF(X210 bolt65ml85ml
2" 2.65" O.D
coaxial flex
pipe
RLX-2.7-10B02"/ 2.65" O.D coaxial flex pipe, studded-direct replacement split EP100RF(X210 bolt65ml85ml
1.5" coaxial
flex pipe
RLX-2.0-10BS 1.5" coaxial flex pipe, studded-direct
replacement split
EP100RF(X2 10 bolt
small
50ml85ml
1.75" coaxial
flex pipe
RLX-2.2-10BS 1.75" coaxial flex pipe, studded-direct
replacement split
EP100RF(X2 10 bolt
small
50ml85ml
2" 2.5" O.D
coaxial flex
pipe
RLX-2.5-10BS2"/ 2.5" O.D coaxial flex pipe, studded-direct replacement split EP100RF(X2 10 bolt
small
65ml85ml
2" 2.65" O.D
coaxial flex
pipe
RLX-2.7-10BS2"/ 2.65" O.D coaxial flex pipe, studded-direct replacement split EP100RF(X2 10 bolt
small
65ml85ml
63mm O.D
fusion, 10
bolt
RLX-63-10B063mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X210 bolt65ml85ml
75mm O.D
fusion, 10
bolt
RLX-75-10B075mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X210 bolt65ml85ml
90mm O.D
fusion, 10
bolt
RLX-90-10B090mm O.D fusion, 8 bolt, studded-direct replacement split EP100RF(X210 bolt85ml85ml

Offset Flanges

Pipe TypePart #Description
3/4" conduitR-07-04-OSOffset flange; 3/4" conduit; 4B
1" conduitR-10-04-OSOffset flange; 1" conduit; 4B
2" FRPR-20-08-OSOffset flange; 2" FRP; 8B
3" FRPR-30-10-OSOffset flange; 3" FRP; 10B
1.5" Coaxial flex-pipeRLX-2.0-10-OSOffset flange; 1.5" flex; 10B
1.75" Coaxial flex-pipeRLX-2.2-10-OSOffset flange; 1.75" flex; 10B
2" Coaxial flex-pipe 2.5" O.DRLX-2.5-10-OSOffset flange; 2" flex; 10B
2" Coaxial flex-pipe 2.65" O.DRLX-2.7-10-OSOffset flange; 2" 2.65 O.D flex; 10B

Accessories and Tools

Part #Description
EP100RFExtra 7 oz. can Bravo retrofit epoxy; use with PVDF pipe
PE-250250ml polyethylene adhesive cartridge; use for poly pipe and poly sump walls; gun
required
NY-260260ml nylon adhesive kit; use with nylon pipe; no gun required
WB-0150ml 20 X expanding water-blocking foam single cartridge; gun required
WB-2050ml 20 X expanding water-blocking foam, case of 20 cartridges; gun required
WB-GWater-blocking foam dispensing gun
T-MG400250ml - 400ml dual cartridge dispensing gun; use with PE-250 cartridge

Direct Replacement Bolted
Fittings
Mounting RingComplete Fitting
FittingSizeID (A)OD (B)Center hole to hole
spacing (C)
Stud to Stud (D)Profile Mounting
Ring and Flange
4 Bolt BSSmall1 13/20"3 1/22 1/2" 1 3/4" 2 5/8"
4 Bolt B0Standard2 1/2"5" 3 1/4"2 5/16"2 3/4"
4 Bolt BLLarge2 1/2"5" 3 1/2" 2 15/32"2 3/4"
8 Bolt BSSmall4"7" 4 1/2"1 3/4" 2 1/2"
8 Bolt B0Standard4"7" 5 1/4"2"2 1/2"
10 Bolt BSSmall4 1/27" 5 13/16"1 13/16"2 11/16"
10 Bolt B0Standard5 5/8"8" 6 3/4"2 1/16"2 11/16"
orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fittings Threaded (TCI) Direct Replacement

Bravo threaded direct replacement retrofits are used for internal, one-sided repairs to eliminate continuous leak points caused by degraded total containment flexible entry boots in polyethylene or FRP sumps. This series is for flat sump walls with existing TCI entry boots. The split design doesn’t require excavation or disconnecting pipe. Models available for size-over-size, coaxial FRP, rigid conduit, and flexible piping. Quality FRP construction provides long term
compliance solutions.

  • No need for excavation or cutting pipe
  • Eliminates rubber boots
  • Attaches to existing TCI threads
  • All common coaxial flex pipes
  • Can be used on poly sumps
  • Offset application available
  • 3-year warranty
  • UL 2447 listed
Retrofit-Fittings-Threaded-(TCI)

Direct replacement Threaded (TCI) FRP Retrofit Entry Fitting – Polyethylene or FRP FLAT SIDED Sumps; Rigid and Flexible Piping; RF EPOXY/PLAS ADH REQ’D; See Flex-pipe ID Chart for Selection

Pipe TypePart ## DescriptionRF EPOXY
REQ'D Qty
Thread
pitch
Pipe
adhesive
Wall
adhesive
3/4" conduit,
UB0075
replacement
RF-07-UB0075 3/4" conduit, UB0075, split,
threaded direct replacement,
brass nut
EP100RFFineNA50ml
3/4" conduit,
UB2000
replacement
RF-07-UB2000 3/4" conduit, UB2000, split,
threaded direct replacement,
brass nut
EP100RFFineNA50ml
1" conduit,
UB0075
replacement
RF-10-UB00751" conduit, UB0075, split, threaded direct replacement, brass nutEP100RFFineNA50ml
1" conduit,
UB2000
replacement
RF-10-UB20001" conduit, UB2000, split, threaded direct replacement, brass nutEP100RFFineNA50ml
3/4" conduit TCI
replacement
RF-07-TCI-CT3/4" TCI repair, split, threaded
direct replacement, plastic nut
EP100RFCourseNA50ml
1" conduit TCI
replacement
RF-10-TCI-CT1" TCI repair, split, threaded
direct replacement, plastic nut
EP100RFCourseNA50ml
2" FRP vapor
penetration
RF-20-TCI-VP2" vapor penetration; split,
threaded direct-replacment
EP100RFFineNA65ml
2" FRP course
thread
RF-20-TCI-CT2" course thread, split, threaded
direct replacement
EP100RFCourseNA85ml
3" FRP course
thread
RF-30-TCI-CT3" course thread, split, threaded
direct replacement
EP100RF (X2) CourseNA85ml
2" FRP fine
thread
RF-20-TCI-FT2" course thread, split, threaded
direct replacement
EP100RF (X2) FineNA85ml
3" FRP fine
thread
RF-30-TCI-FT3" course thread, split, threaded
direct replacement
EP100RF (X2) FineNA85ml
1.5" flex course
thread
RLX-2.0-TCICT1.5" course thread, split, threaded direct replacementEP100RF (X2) Course50ml85ml
2" 2.5" O.D flex
course thread
RLX-2.5-TCICT2"/ 2.65" O.D flex course thread,
split, threaded direct replacement
EP100RF (X2) Course65ml85ml
2" 2.65" O.D flex
course thread
RLX-2.7-TCICT2"/ 2.65" O.D flex course thread,
split, threaded direct replacement
EP100RF (X2) Course65ml85ml
1.5" flex fine
thread
RLX-2.0-TCI-FT1.5" flex fine thread, split, threaded direct replacementEP100RF (X2) Fine50ml85ml
2" 2.5" O.D flex
fine thread
RLX-2.5-TCI-FT2"/ 2.5" flex fine thread, split,
threaded direct replacement
EP100RF (X2) Fine65ml85ml
2" 2.65" O.D flex
fine thread
RLX-2.7-TCI-FT2"/ 2.65" flex fine thread, split,
threaded direct replacement
EP100RF (X2) Fine65ml85ml
63mm O.D fusion
course thread
RLX-63-TCI-CT63mm O.D fusion course thread,
split, threaded direct replacement
EP100RF (X2) Course65ml85ml
75mm O.D fusion
course thread
RLX-75-TCI-CT75mm O.D fusion course thread,
split, threaded direct replacement
EP100RF (X2) Course65ml85ml
90mm O.D fusion
course thread
RLX-90-TCI-CT90mm O.D fusion course thread,
split, threaded direct replacement
EP100RF (X2) Course85ml85ml

Accessories and Tools

Part #Description
EP100RFExtra 7 oz. can Bravo retrofit epoxy; use with PVDF pipe
PE-250250ml polyethylene adhesive cartridge; use for poly pipe and poly sump walls; gun
required
NY-260260ml nylon adhesive kit; use with nylon pipe; no gun required
WB-0150ml 20 X expanding water-blocking foam single cartridge; gun required
WB-2050ml 20 X expanding water-blocking foam, case of 20 cartridges; gun required
WB-GWater-blocking foam dispensing gun
T-MG400250ml - 400ml dual cartridge dispensing gun; use with PE-250 cartridge

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fitting SD-AB Series

The SD-AB Series is used for double-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in doublewall sumps. It repairs both interior and exterior leaks with excavation. The split design doesn’t require disconnecting pipe. Models available for all common FRP piping and rigid conduit. Quality FRP construction provides long term compliance solutions.

  • Double-sided repair, excavation required
  • Models available for flat or round walls
  • 30-year warranty
  • Installation corrects both interior and exterior wall leaks
  • AB2481 compliant
  • UL2447 Listed
Retrofit-Fitting-SD-AB-Series

Retrofit SD-AB Series Double-Sided Split FRP Retrofit Entry Fittings for Rigid Pipe
Flat Doublewall FRP Sumps (Excavation Required)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
1/2" conduit double-sidedRF-05-03-F1/2" conduit, double-sided split for flat
doublewall sumps
EP100RF (X2)7"
3/4" conduit double-sided RF-07-03-F3/4" conduit, double-sided split for flat
doublewall sumps
EP100RF (X2)7"
1" conduit double-sided RF-10-03-F1" conduit, double-sided split for flat
doublewall sumps
EP100RF (X2)7"
2" FRP double-sided RF-20-03-F 2" FRP double-sided split for flat
doublewall sumps
EP100RF (X2)9"
3" FRP double-sided RF-30-03-F 2" FRP double-sided split for round
doublewall sumps
EP100RF (X4)9"
4" FRP double-sided RF-40-03-F4" FRP double-sided split for flat
doublewall sumps
EP100RF (X4)9"
2" LCX double-sidedRF-20L-03-F2" LCX double-sided split for flat
doublewall sumps
EP100RF (X4)9"
3" LCX double-sidedRF-30L-03-F3" LCX double-sided split for flat
doublewall sumps
EP100RF (X4)9"

Retrofit SD-AB Series Double-Sided Split FRP Retrofit Entry Fittings for Rigid Pipe
Round Doublewall FRP Sumps (Excavation Required)

Pipe TypePart #DescriptionEPOXY REQ'D
Qty
A
1/2" conduit double-sidedRF-05-03-R1/2" conduit, double-sided split for round
doublewall sumps
EP100RF (X2)7"
3/4" conduit double-sidedRF-07-03-R3/4" conduit, double-sided split for round
doublewall sumps
EP100RF (X2)7"
1" conduit double-sidedRF-10-03-R 1" conduit, double-sided split for round doublewall
sumps
EP100RF (X2)7"
2" FRP double-sidedRF-20-03-R2" FRP double-sided split for round doublewall
sumps
EP100RF (X2)9"
3" FRP double-sidedRF-30-03-R3" FRP double-sided split for round doublewall
sumps
EP100RF (X4)9"
4" FRP double-sidedRF-40-03-R4" FRP double-sided split for round doublewall
sumps
EP100RF (X4)9"
2" LCX double-sidedRF-20L-03-R 2" LCX double-sided split for round doublewall
sumps
EP100RF (X4)9"
3" LCX double-sidedRF-30L-03-R 3" LCX double-sided split for round doublewall
sumps
EP100RF (X4)9"

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fitting RLX-SD-AB

The FLX-SD-AB Series is used for double-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in doublewall sumps. It repairs both interior and exterior leaks with excavation. The split design doesn’t require disconnecting pipe. Models available for all common flexible and semirigid piping. Quality FRP construction provides long term compliance solutions.

  • Double-sided repair, excavation required
  • Models available for flat or round walls
  • 30-year warranty
  • Installation corrects both interior and exterior wall leaks
  • FRP sleeve seals to plastic piping
  • AB2481 compliant
  • UL2447 Listed
Retrofit-Fitting-FLX-SD-AB-Series

FLX-SD-AB Series Double-Sided Split FRP Retrofit Entry Fittings for
Flex-Pipe Flat Doublewall FRP Sumps (Excavation Required)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
1.5" flex double-sidedRLX-2.0-03-F1.5" flex double-sided split for flat doublewall
sumps
EP100RF (X4)9"
2" (2.5" O.D) flex doublesidedRLX-2.5-03-F 2" 2.5" O.D flex, double-sided split for flat
doublewall sumps
EP100RF (X4)9"
2" (2.65" O.D) flex doublesidedRLX-2.7-03-F 2" 2.65" O.D flex, double-sided split for flat
doublewall sumps
EP100RF (X4)9"

FLX-SD-AB Series Double-Sided Split FRP Retrofit Entry Fittings for
Flex-Pipe Round Doublewall FRP Sumps (Excavation Required)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
1.5" flex double-sided RLX-2.0-03-R 1.5" flex double-sided split for round
doublewall sumps
EP100RF (X4)9"
2" 2.5" O.D flex doublesided RLX-2.5-03-R2"/ 2.5" O.D flex, double-sided split for round
doublewall sumps
EP100RF (X4)9"
2" 2.65" O.D flex doublesided RLX-2.7-03-R2"/ 2.65" O.D flex, double-sided split for round
doublewall sumps
EP100RF (X4)9"

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fittings BLR Series

The BLR Series is used for internal, one-sided repairs to eliminate continuous leak points caused by degraded Blueline Kwik-Fit flexible entry boots in doublewall sumps. It repairs both interior and exterior leaks without excavation. The split design doesn’t require disconnecting pipe. Models available for all common FRP piping and rigid conduit. Quality FRP construction provides long term compliance solutions.

  • No need to break concrete or disconnect pipe
  • Models available for flat or round walls
  • 30-year warranty
  • Installation corrects both interior and exterior wall leaks
  • AB2481 compliant
  • UL2447 Listed
Retrofit-BLR-Series-Doublewall

BLR Series Interior Installation Split FRP Retrofit Entry Fittings for Rigid Pipe Flat Doublewall FRP Sumps; Blueline Kwik-Fit Replacements (No Excavation Required)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
3/4" galvanized conduitRF-07-04-F3/4" galvanized conduit, interior installation split
for flat doublewall sumps
EP100RF (X2)7"
1" galvanized conduit RF-10-04-F 1" galvanized conduit, interior installation split for
flat doublewall sumps
EP100RF (X2)7"
3/4" Rob Roy conduitRF-07R-04-F3/4" Rob Roy conduit, interior installation split for
flat doublewall sumps
EP100RF (X2)7"
1" Rob Roy conduitRF-10R-04-F1" Rob Roy conduit, interior installation split for
flat doublewall sumps
EP100RF (X2)7"
2" FRPRF-20-04-F2" FRP, interior installation split for flat doublewall
sumps
EP100RF (X3)9"
3" FRPRF-30-04-F3" FRP, interior installation split for flat doublewall
sumps
EP100RF (X3)9"
4" FRPRF-40-04-F4" FRP, interior installation split for flat doublewall
sumps
EP100RF (X3)9"

BLR Series Interior Installation Split FRP Retrofit Entry Fittings for Rigid Pipe, Round Doublewall FRP Sumps; Blueline Kwik-Fit Replacements (No Excavation)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
3/4" galvanized conduitRF-07-04-R3/4" galvanized conduit, interior installation split
for round doublewall sumps
EP100RF (X2)7"
1" galvanized conduitRF-10-04-R1" galvanized conduit, interior installation split
for round doublewall sumps
EP100RF (X2)7"
3/4" Rob Roy conduitRF-07R-04-R3/4" Rob Roy conduit, interior installation split for
round doublewall sumps
EP100RF (X2)7"
1" Rob Roy conduitRF-10R-04-R1" Rob Roy conduit, interior installation split for
round doublewall sumps
EP100RF (X2)7"
2" FRPRF-20-04-R2" FRP, interior installation split for roiund
doublewall sumps
EP100RF (X3)9"
3" FRPRF-30-04-R3" FRP, interior installation split for roiund
doublewall sumps
EP100RF (X3)9"
4" FRPRF-40-04-R4" FRP, interior installation split for roiund
doublewall sumps
EP100RF (X3)9"

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fittings INR Series

The BLR Series is used for internal, one-sided repairs to eliminate continuous leak points caused by degraded Blueline Kwik-Fit flexible entry boots in doublewall sumps. It repairs both interior and exterior leaks without excavation. The split design doesn’t require disconnecting pipe. Models available for all common FRP piping and rigid conduit. Quality FRP construction provides long term compliance solutions.

  • No need to break concrete or disconnect pipe
  • Models available for flat or round walls
  • 30-year warranty
  • Installation corrects both interior and exterior wall leaks
  • AB2481 compliant
  • UL2447 Listed
Retrofit-INR-Series

INR Series Interior Installation Split FRP Retrofit Entry Fittings for Rigid Pipe
Flat Doublewall FRP Sumps; Universal Replacement (not Kwik-Fit) (No Excavation)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
3/4" galvanized conduit RF-07-05-F3/4" galvanized, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
1" galvanized conduitRF-10R-05-F1" galvanized, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
3/4" Rob Roy conduitRF-10-05-F3/4" Rob Roy, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
1" Rob Roy conduit RF-10R-05-F1" Rob Roy, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
2" FRPRF-20-05-F2" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"
3" FRPRF-30-05-F3" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"
4" FRPRF-40-05-F4" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"

INR Series Interior Installation Split FRP Retrofit Entry Fittings for Rigid Pipe
Round Doublewall FRP Sumps; Universal Replacement (not Kwik-Fit) (No Excavation)

Pipe TypePart # DescriptionEPOXY REQ'D QtyFlange
Diameter
3/4" galvanized conduitRF-07-05-R 3/4" galvanized, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
1" galvanized conduitRF-10-05-R1" galvanized, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
3/4" Rob Roy conduitRF-07R-05-R3/4" Rob Roy, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
1" Rob Roy conduitRF-10R-05-R1" Rob Roy, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
2" FRPRF-20-05-R2" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"
3" FRPRF-30-05-R3" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"
4" FRPRF-40-05-R4" FRP interior installation split for flat doublewall
sumps
EP100RF (X3)9"

orders@sbravo.com
RETROFIT FITTINGS

Retrofit Fitting RLX INR Series

The FLX INR Series is used for internal, one-sided repairs to eliminate continuous leak points caused by degraded flexible entry boots in doublewall sumps. It repairs both interior and exterior leaks without excavation. The split design doesn’t require disconnecting pipe. Models available for all common flex-pipe and semi-rigid piping. Quality FRP construction provides long term
compliance solutions.

  • No need to break concrete or disconnect pipe
  • Models available for flat or round walls
  • 30-year warranty
  • FRP sleeve seals to plastic piping
  • Installation corrects both interior and exterior wall leaks
  • AB2481 compliant
  • UL2447 Listed
Retrofit-RLX-INR-Series

RLX INR Series Interior Installation Split FRP Retrofit Entry Fittings for Flex Pipe,
Flat Doublewall FRP Sumps; Universal Replacement (not Kwik-Fit) (No Excavation)

Pipe TypePart #DescriptionEPOXY REQ'D Qty Flange
Diameter
3/4" flex RLX-1.4-05-F3/4" flex, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
1.5" flexRLX-2.0-05-F 1.5" flex, interior installation split for flat
doublewall sumps
EP100RF (X2)7"
2" 2.5" O.D flexRLX-2.5-05-F2" 2.5" flex, interior installation split for flat
doublewall sumps
EP100RF (X2) 9"
2" 2.65" O.D flexRLX-2.7-05-F 2" 2.65" flex, interior installation split for flat
doublewall sumps
EP100RF (X2)9"
63mm O.D fusion pipe RLX-63-05-F63mm O.D fusion pipe, interior installation split
for flat doublewall sumps
EP100RF (X2)9"
75mm O.D fusion pipeRLX-75-05-F75mm O.D fusion pipe, interior installation split
for flat doublewall sumps
EP100RF (X2)9"
90mm O.D fusion pipeRLX-90-05-F90mm O.D fusion pipe, interior installation split
for flat doublewall sumps
EP100RF (X2)9"
110mm O.D fusion pipeRLX-110-05-F 110mm O.D fusion pipe, interior installation
split for flat doublewall sumps
EP100RF (X3)11"
125mm O.D fusion pipeRLX-125-05-F 125mm O.D fusion pipe, interior installation
split for flat doublewall sumps
EP100RF (X3)11"

RLX INR Series Interior Installation Split FRP Retrofit Entry Fittings for Flex Pipe
Round Doublewall FRP Sumps; Universal Replacement (not Kwik-Fit) (No Excavation)

Pipe TypePart #DescriptionEPOXY REQ'D QtyFlange
Diameter
3/4" flex RLX-1.4-05-R 3/4" flex, interior installation split for round
doublewall sumps
EP100RF (X2)7"
1.5" flexRLX-2.0-05-R 1.5" flex, interior installation split for round
doublewall sumps
EP100RF (X2)7"
2" 2.5" O.D flexRLX-2.5-05-R2" 2.5" flex, interior installation split for round
doublewall sumps
EP100RF (X2)9"
2" 2.65" O.D flexRLX-2.7-05-R 2" 2.65" flex, interior installation split for round
doublewall sumps
EP100RF (X2)9"
63mm O.D fusion pipeRLX-63-05-R63mm O.D fusion pipe, interior installation split
for round doublewall sumps
EP100RF (X2)9"
75mm O.D fusion pipeRLX-75-05-R75mm O.D fusion pipe, interior installation split
for round doublewall sumps
EP100RF (X2)9"
90mm O.D fusion pipeRLX-90-05-R 90mm O.D fusion pipe, interior installation split
for round doublewall sumps
EP100RF (X2)9"
110mm O.D fusion pipe RLX-110-05-R110mm O.D fusion pipe, interior installation
split for round doublewall sumps
EP100RF (X3)11"
125mm O.D fusion pipeRLX-125-05-R 125mm O.D fusion pipe, interior installation
split for round doublewall sumps
EP100RF (X3)11"

orders@sbravo.com
RETROFIT FITTINGS
arrow Go Back
circle

Coming Soon…

circle
New Installation Guides Coming Soon

Please Feel Free to Contact Customer Service

800.282.7286

circle

circle

“Accessibility Statement” for SBravo.com

Bravo Inc. is committed to ensuring digital accessibility for people with disabilities. We are continually improving the user experience for everyone, and applying the relevant accessibility standards.

Measures to support accessibility

Bravo Inc. takes the following measures to ensure accessibility of SBravo.com:

  • Include accessibility as part of our mission statement.
  • Include accessibility throughout our internal policies.
  • Integrate accessibility into our procurement practices.
  • Assign clear accessibility targets and responsibilities.
  • Employ formal accessibility quality assurance methods.

Conformance status

The Web Content Accessibility Guidelines (WCAG) defines requirements for designers and developers to improve accessibility for people with disabilities. It defines three levels of conformance: Level A, Level AA, and Level AAA. SBravo.com is fully conformant with WCAG 2.1 level AA. Fully conformant means that the content fully conforms to the accessibility standard without any exceptions.

Feedback

We welcome your feedback on the accessibility of SBravo.com. Please let us know if you encounter accessibility barriers on SBravo.com:

We try to respond to feedback within 3 Business Days.

Technical specifications

Accessibility of SBravo.com relies on the following technologies to work with the particular combination of web browser and any assistive technologies or plugins installed on your computer:

  • HTML
  • WAI-ARIA
  • CSS
  • JavaScript
Font Resize